Specifications:
According to test Standard: BIFMA X5.1-2002, Test No. 17
Applicability: This test applies to pedestal base chairs with casters.
Purpose of Test: this machine is designed to evaluate the ability of a chair base and casters to withstand fatigue stresses and wear caused by moving the chair back and forth.
1. Applicability: This test applies to pedestal base chairs with casters.
Purpose of Test: this machine is designed to evaluate the ability of a chair base and casters to withstand fatigue stresses and wear caused by moving the chair back and forth.
2. Functions:
- Test speed: 10 ± 2 times.
- Test stroke: 762mm (30in).
- Load: 102kg (225lb).
- Test cycle: 100,000 times.
- Testing frequency can be pre-set. Once the pre-set level is reached, the machine stop automatically .
- Automatic endpoints: automatic detection of breakdown point while the test specimen breaks.
- Counter: 999,999
- Equipped with a protection cover.
- Loading weight is adjustable.
- Adopted pneumatic cylinder for ease of loading of weights.
For more information, please contact with us.
无标题¤å档
Note: Specifications are subject to change without notice.
|